| Applications |
| |
 |
Warehouses |
| |
 |
Parkings |
| |
 |
Painting Installations |
| |
 |
Iron and steel industries Foundries |
| |
 |
Chemical industry Laboratories |
| |
 |
Car industries |
| |
 |
Battery rooms |
| |
| |
|
|
|
| Documentation |
| |
| |
| |
|
|
| |
| Description |
| |
| |
| |
Range of flameproof plate mounted axial fans in accordance to ATEX Directive. Mounting plate manufactured from galvanised sheet steel fitted with an internal aluminium ring and motor support manufactured from heavy gauge aluminium plate. The whole assembly is protected by aluminium paint finish B-0920. Impellers manufactured from one piece die-cast aluminium with aerofoil profile fixed blades and finished in a high temperature paint coating (red colour). Available, depending upon the model, with single or three phase motors in 4, 6 or 8 poles. |
| |
| Motors |
| |
| |
| |
All motors are IP55, Class F insulation. All motors incorporate ball bearings greased for life. Electrical supplies:
- Single phase 230V-50Hz.
- Three phase 230/400V-50Hz.
|
| |
| Additional Information |
| |
| |
| |
Standard air direction: form (A) configuration (Motor over Impeller). For the single phase motors, the capacitor is provided not fitted on the fan. It must be installed outside of the ATEX area or within an electrical main board complying with ATEX Directive. On request Air direction: form (B) configuration (Impeller over Motor) only for 450 and 560 models. Flame proof axial flow fans in accordance to ATEX Directive:
- Standard single phase motors Ex II2G EExd IIBT4 or T5.
- Standard three phase motors Ex II2G EExd IIBT3 or T5.
- On request EExd IICT3 or T4 motors.
Working temperatures up to 40 ºC. |
| |
|